C $Header: /u/gcmpack/MITgcm/pkg/aim_compon_interf/atm_export_runoff.F,v 1.1 2003/12/15 02:44:48 jmc Exp $
C $Name: $
#include "CPP_OPTIONS.h"
CStartOfInterface
SUBROUTINE ATM_EXPORT_RUNOFF( myThid )
C /==========================================================\
C | SUBROUTINE ATM_EXPORT_RUNOFF |
C | o Routine for exporting atmos. RunOff from land bucket |
C | to coupling layer. |
C |==========================================================|
C | This version talks to the MIT Coupler. It uses the MIT |
C | Coupler "checkpoint1" library calls. |
C \==========================================================/
IMPLICIT NONE
C == Global variables ==
#include "SIZE.h"
#include "EEPARAMS.h"
#include "ATMCPL.h"
#include "ATMIDS.h"
C == Routine arguments ==
C myThid - Thread number for this instance of the routine
INTEGER myThid
CEndOfInterface
C == Local variables ==
C recipAvT :: Temp. for holding reciprocal of averaging period.
C I,J,K,II :: Loop counters
C bi, bj ::
_RL recipAvT
INTEGER I
INTEGER J
INTEGER K
INTEGER II
INTEGER bi
INTEGER bj
C Convert time integrated heatflux to mean value ready for
C export.
DO bj=myByLo(myThid),myByHi(myThid)
DO bi=myBxLo(myThid),myBxHi(myThid)
IF ( ABS(RunOffTime(bi,bj) -1. _d 0).GT. 1. _d -12
& .AND. RunOffTime(bi,bj) .NE. 0. ) THEN
recipAvT = 1. _d 0/RunOffTime(bi,bj)
DO J=1,sNy
DO I=1,sNx
RunOffFlux(I,J,bi,bj) = RunOffFlux(I,J,bi,bj)*recipAvT
ENDDO
ENDDO
WRITE(errorMessageUnit,*)'ATM_EXPORT_RUNOFF: 1-CountTime=',
& bi,bj,1.-RunOffTime(bi,bj)
ENDIF
ENDDO
ENDDO
C o Send freshwater flux to coupling layer.
CALL COMPSEND_R8TILES( atmRunOffName,
I sNx, OLx, sNy, OLy, 1, nSx, nSy, RunOffFlux )
C Reset fresh water flux to start accumulating again.
DO bj=myByLo(myThid),myByHi(myThid)
DO bi=myBxLo(myThid),myBxHi(myThid)
RunOffTime(bi,bj) = 0.
DO J=1,sNy
DO I=1,sNx
RunOffFlux(I,J,bi,bj) = 0.
ENDDO
ENDDO
ENDDO
ENDDO
RETURN