File |
Line number |
Procedure |
Code |
./pkg/exf/exf_readparms.F |
320 |
EXF_READPARMS |
exf_monFreq = monitorFreq |
./model/inc/PARAMS.h |
829 |
NO PROCEDURE |
& diagFreq, taveFreq, tave_lastIter, monitorFreq, adjMonitorFreq, |
./model/inc/PARAMS.h |
950 |
NO PROCEDURE |
_RL monitorFreq |
./pkg/land/land_readparms.F |
128 |
LAND_READPARMS |
land_monFreq = monitorFreq |
./pkg/monitor/monitor.F |
51 |
MONITOR |
IF ( DIFFERENT_MULTIPLE(monitorFreq,myTime,deltaTClock) ) THEN |
./model/src/config_summary.F |
760 |
CONFIG_SUMMARY |
CALL WRITE_0D_RL( monitorFreq, INDEX_NONE,'monitorFreq =', |
./pkg/obcs/obcs_monitor.F |
95 |
OBCS_MONITOR |
IF ( OBCS_monitorFreq .NE. monitorFreq |
./pkg/obcs/obcs_readparms.F |
282 |
OBCS_READPARMS |
OBCS_monitorFreq = monitorFreq |
./pkg/ptracers/ptracers_monitor.F |
100 |
PTRACERS_MONITOR |
IF ( PTRACERS_monitorFreq .NE. monitorFreq |
./pkg/ptracers/ptracers_readparms.F |
106 |
PTRACERS_READPARMS |
PTRACERS_monitorFreq = monitorFreq |
./model/src/forward_step.F |
1174 |
FORWARD_STEP |
IF ( monitorFreq.GT.0. .OR. adjMonitorFreq.GT.0. ) THEN |
./pkg/sbo/sbo_readparms.F |
71 |
SBO_READPARMS |
sbo_monFreq = monitorFreq |
./pkg/seaice/seaice_readparms.F |
513 |
SEAICE_READPARMS |
SEAICE_monFreq = monitorFreq |
./pkg/thsice/thsice_readparms.F |
169 |
THSICE_READPARMS |
thSIce_monFreq = monitorFreq |
./model/src/ini_parms.F |
1031 |
INI_PARMS |
IF (monitorFreq.LT.0.) THEN |
./model/src/ini_parms.F |
1032 |
INI_PARMS |
monitorFreq=0. |
./model/src/ini_parms.F |
1033 |
INI_PARMS |
IF (dumpFreq.NE.0.) monitorFreq=dumpFreq |
./model/src/ini_parms.F |
1034 |
INI_PARMS |
IF (diagFreq.NE.0..AND.diagFreq.LT.monitorFreq) |
./model/src/ini_parms.F |
1035 |
INI_PARMS |
& monitorFreq=diagFreq |
./model/src/ini_parms.F |
1036 |
INI_PARMS |
IF (taveFreq.NE.0..AND.taveFreq.LT.monitorFreq) |
./model/src/ini_parms.F |
1037 |
INI_PARMS |
& monitorFreq=taveFreq |
./model/src/ini_parms.F |
1038 |
INI_PARMS |
IF (chkPtFreq.NE.0..AND.chkPtFreq.LT.monitorFreq) |
./model/src/ini_parms.F |
1039 |
INI_PARMS |
& monitorFreq=chkPtFreq |
./model/src/ini_parms.F |
1040 |
INI_PARMS |
IF (pChkPtFreq.NE.0..AND.pChkPtFreq.LT.monitorFreq) |
./model/src/ini_parms.F |
1041 |
INI_PARMS |
& monitorFreq=pChkPtFreq |
./model/src/ini_parms.F |
1042 |
INI_PARMS |
IF (monitorFreq.EQ.0.) monitorFreq=deltaTClock |
./model/src/ini_parms.F |
263 |
INI_PARMS |
& diagFreq, monitorFreq, adjMonitorFreq, monitorSelect, |
./model/src/packages_boot.F |
434 |
PACKAGES_BOOT |
locFlag = monitorFreq.GT.0. |
./model/src/packages_check.F |
185 |
PACKAGES_CHECK |
IF (monitorFreq.NE.0.) CALL PACKAGES_ERROR_MSG( |
./model/src/set_defaults.F |
346 |
SET_DEFAULTS |
monitorFreq = -1. |
./model/src/solve_for_pressure.F |
323 |
SOLVE_FOR_PRESSURE |
IF ( DIFFERENT_MULTIPLE(monitorFreq,myTime,deltaTClock) |
./model/src/solve_for_pressure.F |
426 |
SOLVE_FOR_PRESSURE |
IF ( DIFFERENT_MULTIPLE(monitorFreq,myTime,deltaTClock) |
./model/src/thermodynamics.F |
119 |
THERMODYNAMICS |
& DIFFERENT_MULTIPLE( monitorFreq, wrTime, deltaTClock ) |
./model/src/turnoff_model_io.F |
58 |
TURNOFF_MODEL_IO |
monitorFreq = 0. |