Next: 7.5 Grid Generation
Up: 7.4 Monitor: Simulation state
Previous: 7.4.1 Introduction
Contents
7.4.2 Using Monitor
As with most packages, monitor can be turned on or off at
compile and/or run times using the packages.conf and
data.pkg files.
The monitor output can be sent to the standard output channel, to an
mnc-generated file, or to both simultaneously. For
mnc output, the flag:
monitor_mnc=.TRUE.,
should be set within the data.mnc file. For output to both
ASCII and mnc, the flag
outputTypesInclusive=.TRUE.,
should be set within the PARM03 section of the main
data file. It should be noted that the
outputTypesInclusive flag will make ALL kinds of
output (that is, everything written by mdsio, mnc,
and monitor) simultaneously active so it should be used only
with caution-and perhaps only for debugging purposes.
mitgcm-support@mitgcm.org
Copyright © 2006
Massachusetts Institute of Technology |
Last update 2011-01-09 |
|
|