7.4.1 Introduction
The monitor package is primarily intended as a convenient
method for calculating and writing the following statistics:
minimum, maximum, mean, and standard deviation
for spatially distributed fields. By default, monitor output
is sent to the ``standard output'' channel where it appears as ASCII
text containing a %MON string such as this example:
(PID.TID 0000.0001) %MON time_tsnumber = 3
(PID.TID 0000.0001) %MON time_secondsf = 3.6000000000000E+03
(PID.TID 0000.0001) %MON dynstat_eta_max = 1.0025466645951E-03
(PID.TID 0000.0001) %MON dynstat_eta_min = -1.0008899950901E-03
(PID.TID 0000.0001) %MON dynstat_eta_mean = 2.1037438449350E-14
(PID.TID 0000.0001) %MON dynstat_eta_sd = 5.0985228723396E-04
(PID.TID 0000.0001) %MON dynstat_eta_del2 = 3.5216706549525E-07
(PID.TID 0000.0001) %MON dynstat_uvel_max = 3.7594045977254E-05
(PID.TID 0000.0001) %MON dynstat_uvel_min = -2.8264287531564E-05
(PID.TID 0000.0001) %MON dynstat_uvel_mean = 9.1369201945671E-06
(PID.TID 0000.0001) %MON dynstat_uvel_sd = 1.6868439193567E-05
(PID.TID 0000.0001) %MON dynstat_uvel_del2 = 8.4315445301916E-08
The monitor text can be readily parsed by the
testreport script to determine, somewhat crudely but quickly,
how similar the output from two experiments are when run on different
platforms or before/after code changes.
The monitor output can also be useful for quickly diagnosing
practical problems such as CFL limitations, model progress (through
iteration counts), and behavior within some packages that use it.